{"title":"Compact RCBO 1P+N 1Module","description":"","products":[{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c32a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C32A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 32A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278433941,"sku":"NB2LE6-32A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-32A.png?v=1775699543"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c40a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C40A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 40A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278630549,"sku":"NB2LE6-40A","price":35.27,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-40A.png?v=1775635165"},{"product_id":"chint-busbar-needle-type-54-way-for-nb2le-compact-rcbos","title":"CHINT BUSBAR NEEDLE-TYPE 54-WAY FOR NB2LE COMPACT RCBO'S","description":"\u003cp\u003eThe \u003cstrong\u003eCHINT CBB-2 Busbar\u003c\/strong\u003e is designed for efficient power distribution and connection of modular low-voltage devices with 18 mm widths. It ensures safe, reliable, and simplified wiring in distribution panels. Engineered under IEC 60947-7 standards, it provides high conductivity, strong mechanical performance, and compatibility across CHINT’s NB1 and NB2 series modular devices.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: IEC 60947-7 compliant \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar Types\u003c\/strong\u003e: Pin in 18mm(upper interface)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Sectional Area\u003c\/strong\u003e: 10 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current\u003c\/strong\u003e: 63 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThickness\u003c\/strong\u003e: 1.5 mm copper bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation\u003c\/strong\u003e: Suitable for 18 mm modular devices (MCBs, RCCBs, RCBOs, SPDs)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278663317,"sku":"CBB211710","price":72.47,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CBB211710.png?v=1737520297"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c10a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C10A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278761621,"sku":"NB2LE4.5-10A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c16a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C16A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278925461,"sku":"NB2LE4.5-16A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c20a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C20A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278990997,"sku":"NB2LE4.5-20A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c25a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C25A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592279056533,"sku":"NB2LE4.5-25A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c32a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C32A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 32A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592279089301,"sku":"NB2LE4.5-32A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c40a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C40A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 40A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592279122069,"sku":"NB2LE4.5-40A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c10a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C10A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592290295957,"sku":"NB2LE6-10A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-10A.png?v=1775703022"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c16a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C16A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592290328725,"sku":"NB2LE6-16A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-16A.png?v=1775702867"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c20a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C20A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 6A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592290427029,"sku":"NB2LE6-20A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-20A.png?v=1775699838"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c25a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C25A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592290459797,"sku":"NB2LE6-25A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-25A.png?v=1775699707"},{"product_id":"chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos","title":"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S","description":"\u003cp\u003eBusbar side cap 2P 16mm2\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45890033156245,"sku":"CBBSC2P","price":0.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/busbarsidecap.png?v=1775716320"},{"product_id":"chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos","title":"CHINT BUSBAR NEEDLE-TYPE 18-WAY FOR NB2LE COMPACT RCBO'S","description":"\u003cp\u003eThe \u003cstrong\u003eCHINT CBB-2 Busbar\u003c\/strong\u003e is designed for efficient power distribution and connection of modular low-voltage devices with 18 mm widths. It ensures safe, reliable, and simplified wiring in distribution panels. Engineered under IEC 60947-7 standards, it provides high conductivity, strong mechanical performance, and compatibility across CHINT’s NB1 and NB2 series modular devices.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: IEC 60947-7 compliant \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar Types\u003c\/strong\u003e: Pin in 18mm(upper interface)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Sectional Area\u003c\/strong\u003e: 10 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current\u003c\/strong\u003e: 63 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThickness\u003c\/strong\u003e: 1.5 mm copper bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation\u003c\/strong\u003e: Suitable for 18 mm modular devices (MCBs, RCCBs, RCBOs, SPDs)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45890033221781,"sku":"CBB211710\/18","price":27.47,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CBB211710_2018.png?v=1742873036"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c6a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C6A 30mA A-TYPE","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB2LE RCBO\u003c\/strong\u003e Compact is a space-saving and efficient solution for protecting electrical circuits from overloads, short circuits, and earth leakage. Designed with a 1P+N configuration, it combines the functions of an MCB and RCD into a single compact device\u003cstrong\u003e.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWith 30mA sensitivity, and 6kA breaking capacity\u003c\/strong\u003e, this RCBO provides reliable protection for residential and light commercial applications. The C-curve tripping characteristic allows it to handle moderate inrush currents, reducing nuisance tripping in everyday use.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 6A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45890067005589,"sku":"NB2LE6-06A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-40A.png?v=1775635165"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/collections\/NB2LE6-20A_18e2ca38-5c5f-4e80-bc5b-f917733e0e42.png?v=1774575091","url":"https:\/\/e-p-s.com.au\/collections\/compact-rcbo-1p-n-1module.oembed?page=2","provider":"EPS","version":"1.0","type":"link"}