{"title":"RCBO \u0026 Accessories","description":"","products":[{"product_id":"chint-auxiliary-contact-for-nb1-nbh8-nb1l-nbh8le-mcbs-rcbos","title":"CHINT AUXILIARY CONTACT FOR NB1, NBH8, NB1L, NBH8LE MCB'S\/RCBO'S","description":"","brand":"CHINT","offers":[{"title":"EA","offer_id":45592268112021,"sku":"XF9-AUX","price":36.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/XF9-AUX_46c38dcd-4c5c-48b2-959b-b8d5e3942d0c.png?v=1737093812"},{"product_id":"chint-alarm-auxiliary-contact-for-nb1-nbh8-nb1l-nbh8le-mcbs-rcbos","title":"CHINT ALARM AUXILIARY CONTACT FOR NB1, NBH8, NB1L, NBH8LE MCB'S\/RCBO'S","description":"","brand":"CHINT","offers":[{"title":"EA","offer_id":45592268177557,"sku":"XF9J-ALAUX","price":40.38,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/XF9J-ALAUX_75f53b2b-5399-4887-9c7e-771feda3d7ae.png?v=1737093816"},{"product_id":"chint-rcbo-nb1l-1p-n-2-module-10a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB1L 1P+N 2 MODULE 10A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003eThe CHINT NB1L (RCBO) provides complete protection against earth leakage, overload, and short-circuit conditions, ensuring both electrical safety and fire prevention. This RCBO is type A, which detects both AC and pulsing DC residual currents. NB1L RCBO is used for residential and light commercial circuits, particularly those using mixed loads such as lighting, sockets, and small motors. Additionally, this NB1L supports top and bottom wiring, and can be mounted on standard DIN rails using a fast clip-on mechanism for easy installation. With 10 kA breaking capacity and leakage sensitivities of 30mA, the NB1L is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 240 V~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 10 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N 2Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method\u003c\/strong\u003e: 35 mm DIN rail, clip-on installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Direction\u003c\/strong\u003e: From top or bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e: 1P+N: 86 × 36 × 77 (H × W × D)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB1L_RCBO.pdf?v=1775799088\" rel=\"noopener\" target=\"_blank\" title=\"CHINT RCBO NB1L 1P+N 2 MODULE 30mA 10kA C-CURVE TYPE A\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592268832917,"sku":"NB1L-C10","price":43.38,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB1L-C10.png?v=1775790909"},{"product_id":"chint-rcbo-nb1l-1p-n-2-module-16a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB1L 1P+N 2 MODULE 16A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003eThe CHINT NB1L (RCBO) provides complete protection against earth leakage, overload, and short-circuit conditions, ensuring both electrical safety and fire prevention. This RCBO is type A, which detects both AC and pulsing DC residual currents. NB1L RCBO is used for residential and light commercial circuits, particularly those using mixed loads such as lighting, sockets, and small motors. Additionally, this NB1L supports top and bottom wiring, and can be mounted on standard DIN rails using a fast clip-on mechanism for easy installation. With 10 kA breaking capacity and leakage sensitivities of 30mA, the NB1L is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 240 V~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 16 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N 2Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method\u003c\/strong\u003e: 35 mm DIN rail, clip-on installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Direction\u003c\/strong\u003e: From top or bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e: 1P+N: 86 × 36 × 77 (H × W × D)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB1L_RCBO.pdf?v=1775799088\" rel=\"noopener\" target=\"_blank\" title=\"CHINT RCBO NB1L 1P+N 2 MODULE 30mA 10kA C-CURVE TYPE A\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592268865685,"sku":"NB1L-C16","price":43.38,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB1L-C16_462765da-5f2f-4864-9b2f-586e44dc2058.png?v=1775799394"},{"product_id":"chint-rcbo-nb1l-1p-n-2-module-20a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB1L 1P+N 2 MODULE 20A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003eThe CHINT NB1L (RCBO) provides complete protection against earth leakage, overload, and short-circuit conditions, ensuring both electrical safety and fire prevention. This RCBO is type A, which detects both AC and pulsing DC residual currents. NB1L RCBO is used for residential and light commercial circuits, particularly those using mixed loads such as lighting, sockets, and small motors. Additionally, this NB1L supports top and bottom wiring, and can be mounted on standard DIN rails using a fast clip-on mechanism for easy installation. With 10 kA breaking capacity and leakage sensitivities of 30mA, the NB1L is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 240 V~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 20 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N, 2Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method\u003c\/strong\u003e: 35 mm DIN rail, clip-on installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Direction\u003c\/strong\u003e: From top or bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e: 1P+N: 86 × 36 × 77 (H × W × D)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB1L_RCBO.pdf?v=1775799088\" rel=\"noopener\" target=\"_blank\" title=\"CHINT RCBO NB1L 1P+N 2 MODULE 30mA 10kA C-CURVE TYPE A\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592268963989,"sku":"NB1L-C20","price":43.38,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB1L-C20.png?v=1775799741"},{"product_id":"chint-rcbo-nb1l-1p-n-2-module-25a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB1L 1P+N 2 MODULE 25A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003eThe CHINT NB1L (RCBO) provides complete protection against earth leakage, overload, and short-circuit conditions, ensuring both electrical safety and fire prevention. This RCBO is type A, which detects both AC and pulsing DC residual currents. NB1L RCBO is used for residential and light commercial circuits, particularly those using mixed loads such as lighting, sockets, and small motors. Additionally, this NB1L supports top and bottom wiring, and can be mounted on standard DIN rails using a fast clip-on mechanism for easy installation. With 10 kA breaking capacity and leakage sensitivities of 30mA, the NB1L is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 240 V~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 25 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N 2Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method\u003c\/strong\u003e: 35 mm DIN rail, clip-on installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Direction\u003c\/strong\u003e: From top or bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e: 1P+N: 86 × 36 × 77 (H × W × D)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB1L_RCBO.pdf?v=1775799088\" rel=\"noopener\" target=\"_blank\" title=\"CHINT RCBO NB1L 1P+N 2 MODULE 30mA 10kA C-CURVE TYPE A\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592269357205,"sku":"NB1L-C25","price":43.38,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB1L-C25.png?v=1775800512"},{"product_id":"chint-rcbo-nb1l-1p-n-2-module-32a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB1L 1P+N 2 MODULE 32A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003eThe CHINT NB1L (RCBO) provides complete protection against earth leakage, overload, and short-circuit conditions, ensuring both electrical safety and fire prevention. This RCBO is type A, which detects both AC and pulsing DC residual currents. NB1L RCBO is used for residential and light commercial circuits, particularly those using mixed loads such as lighting, sockets, and small motors. Additionally, this NB1L supports top and bottom wiring, and can be mounted on standard DIN rails using a fast clip-on mechanism for easy installation. With 10 kA breaking capacity and leakage sensitivities of 30mA, the NB1L is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Type\u003c\/strong\u003e: Thermo-magnetic release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 240 V~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 32 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N, 2Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve (5–10 In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method\u003c\/strong\u003e: 35 mm DIN rail, clip-on installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Direction\u003c\/strong\u003e: From top or bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e: 1P+N: 86 × 36 × 77 (H × W × D)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB1L_RCBO.pdf?v=1775799088\" rel=\"noopener\" target=\"_blank\" title=\"CHINT RCBO NB1L 1P+N 2 MODULE 30mA 10kA C-CURVE TYPE A\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592269389973,"sku":"NB1L-C32","price":43.38,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB1L-C32.png?v=1775799597"},{"product_id":"chint-rcbo-nb1l-1p-n-2-module-40a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB1L 1P+N 2 MODULE 40A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003eThe CHINT NB1L (RCBO) provides complete protection against earth leakage, overload, and short-circuit conditions, ensuring both electrical safety and fire prevention. This RCBO is type A, which detects both AC and pulsing DC residual currents. NB1L RCBO is used for residential and light commercial circuits, particularly those using mixed loads such as lighting, sockets, and small motors. Additionally, this NB1L supports top and bottom wiring, and can be mounted on standard DIN rails using a fast clip-on mechanism for easy installation. With 10 kA breaking capacity and leakage sensitivities of 30mA, the NB1L is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 240 V~\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 40 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N, 2Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method\u003c\/strong\u003e: 35 mm DIN rail, clip-on installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Direction\u003c\/strong\u003e: From top or bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e: 1P+N: 86 × 36 × 77 (H × W × D)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB1L_RCBO.pdf?v=1775799088\" rel=\"noopener\" target=\"_blank\" title=\"CHINT RCBO NB1L 1P+N 2 MODULE 30mA 10kA C-CURVE TYPE A\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592269488277,"sku":"NB1L-C40","price":43.38,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB1L-C4040A.png?v=1775799996"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-10a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 10A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 10A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592269521045,"sku":"NB3LEU1030-C10","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C10.png?v=1774852603"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-16a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 16A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 16A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003eC Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592269553813,"sku":"NB3LEU1030-C16","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C16.png?v=1774854192"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-20a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 20A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 20A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592269652117,"sku":"NB3LEU1030-C20","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C20.png?v=1774855645"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-25a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 25A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 25A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592269750421,"sku":"NB3LEU1030-C25","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C25.png?v=1774855826"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-32a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 32A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 32A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e32A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592270110869,"sku":"NB3LEU1030-C32","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C32.png?v=1774856003"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-40a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 40A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 40A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e40A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592270209173,"sku":"NB3LEU1030-C40","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C40.png?v=1774856162"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c32a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C32A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 32A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278433941,"sku":"NB2LE6-32A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-32A.png?v=1775699543"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c40a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C40A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 40A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278630549,"sku":"NB2LE6-40A","price":35.27,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-40A.png?v=1775635165"},{"product_id":"chint-busbar-needle-type-54-way-for-nb2le-compact-rcbos","title":"CHINT BUSBAR NEEDLE-TYPE 54-WAY FOR NB2LE COMPACT RCBO'S","description":"\u003cp\u003eThe \u003cstrong\u003eCHINT CBB-2 Busbar\u003c\/strong\u003e is designed for efficient power distribution and connection of modular low-voltage devices with 18 mm widths. It ensures safe, reliable, and simplified wiring in distribution panels. Engineered under IEC 60947-7 standards, it provides high conductivity, strong mechanical performance, and compatibility across CHINT’s NB1 and NB2 series modular devices.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: IEC 60947-7 compliant \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar Types\u003c\/strong\u003e: Pin in 18mm(upper interface)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Sectional Area\u003c\/strong\u003e: 10 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current\u003c\/strong\u003e: 63 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThickness\u003c\/strong\u003e: 1.5 mm copper bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation\u003c\/strong\u003e: Suitable for 18 mm modular devices (MCBs, RCCBs, RCBOs, SPDs)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278663317,"sku":"CBB211710","price":72.47,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CBB211710.png?v=1737520297"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c10a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C10A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278761621,"sku":"NB2LE4.5-10A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c16a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C16A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278925461,"sku":"NB2LE4.5-16A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c20a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C20A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592278990997,"sku":"NB2LE4.5-20A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c25a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C25A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592279056533,"sku":"NB2LE4.5-25A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c32a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C32A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 32A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592279089301,"sku":"NB2LE4.5-32A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-4-5ka-c40a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 4.5kA C40A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 4.5 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 40A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (In): \u003c\/strong\u003e4.5kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592279122069,"sku":"NB2LE4.5-40A","price":22.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE4-40A.png?v=1775703267"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-10a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 10A 30mA 6kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEG RCBO\u003c\/strong\u003e is a compact and reliable solution for combined overcurrent and residual current protection. Designed with a 1P+N configuration and single-module width, it saves space while delivering high-performance safety for modern electrical installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWith a 30mA sensitivity and 6kA breaking capacity\u003c\/strong\u003e, this RCBO ensures effective protection against overloads, short circuits, and earth leakage faults. The C-curve tripping characteristic allows it to handle moderate inrush currents, making it suitable for a wide range of applications. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThe Type A \u003c\/strong\u003eRCD functionality provides enhanced protection by detecting both AC and pulsating DC residual currents, making it ideal for circuits with electronic devices.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e10A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e1P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eC-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A (AC + pulsing DC)\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e240V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e6kA\u003cstrong\u003e\u003cbr\u003eMounting Method: \u003c\/strong\u003e35 mm DIN rail (EN 60715), quick clip-on design.\u003cstrong\u003e\u003cbr\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEG-40_RCBO.pdf?v=1774580645\" rel=\"noopener\" target=\"_blank\" title=\"NB3LEG-40 Residual Current Circuit Breaker with Over-current Protection (Electronic)\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592284922005,"sku":"NB3LEG630-C10","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C10_db14bc28-baa3-4d80-9be6-f9e4bfeb22d5.png?v=1774582125"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-16a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 16A 30mA 6kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEG RCBO\u003c\/strong\u003e is a compact and reliable solution for combined overcurrent and residual current protection. Designed with a 1P+N configuration and single-module width, it saves space while delivering high-performance safety for modern electrical installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWith a 30mA sensitivity and 6kA breaking capacity\u003c\/strong\u003e, this RCBO ensures effective protection against overloads, short circuits, and earth leakage faults. The C-curve tripping characteristic allows it to handle moderate inrush currents, making it suitable for a wide range of applications. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThe Type A\u003c\/strong\u003e RCD functionality provides enhanced protection by detecting both AC and pulsating DC residual currents, making it ideal for circuits with electronic devices.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e16A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e1P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eC-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A (AC + pulsing DC)\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e240V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e6kA\u003cstrong\u003e\u003cbr\u003eMounting Method: \u003c\/strong\u003e35 mm DIN rail (EN 60715), quick clip-on design.\u003cstrong\u003e\u003cbr\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592285085845,"sku":"NB3LEG630-C16","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C16.png?v=1774842921"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-20a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 20A 30mA 6kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEG RCBO\u003c\/strong\u003e is a compact and reliable solution for combined overcurrent and residual current protection. Designed with a 1P+N configuration and single-module width, it saves space while delivering high-performance safety for modern electrical installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWith a 30mA sensitivity and 6kA breaking capacity\u003c\/strong\u003e, this RCBO ensures effective protection against overloads, short circuits, and earth leakage faults. The C-curve tripping characteristic allows it to handle moderate inrush currents, making it suitable for a wide range of applications. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThe Type A\u003c\/strong\u003e RCD functionality provides enhanced protection by detecting both AC and pulsating DC residual currents, making it ideal for circuits with electronic devices.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e20A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e1P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eC-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A (AC + pulsing DC)\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e240V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e6kA\u003cstrong\u003e\u003cbr\u003eMounting Method: \u003c\/strong\u003e35 mm DIN rail (EN 60715), quick clip-on design.\u003cstrong\u003e\u003cbr\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEG-40_RCBO.pdf?v=1774580645\" rel=\"noopener\" target=\"_blank\" title=\"NB3LEG-40 Residual Current Circuit Breaker with Over-current Protection (Electronic)\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592285184149,"sku":"NB3LEG630-C20","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C20.png?v=1774843192"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-25a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 25A 30mA 6kA C-CURVE TYPE A","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Combined protection against overload, short-circuit, and residual current leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping type: \u003c\/strong\u003eElectronic (integrated residual current and thermal-magnetic release)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC Curve (5-10In): \u003c\/strong\u003eFor resistive and inductive loads with low inrush currents\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003e35 mm\u003cstrong\u003e \u003c\/strong\u003eDIN rail (EN 60715), quick clip-on design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications: \u003c\/strong\u003eResidential distribution boards, lighting control, and general-purpose low-voltage systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e25A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e1P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type:\u003c\/strong\u003e Type A (AC + pulsing DC)\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eResidual Making and Breaking Capacity (I△m):\u003c\/strong\u003e 3kA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 6kA\u003cbr\u003e\u003cstrong\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEG-40_RCBO.pdf?v=1774580645\" rel=\"noopener\" target=\"_blank\" title=\"NB3LEG-40 Residual Current Circuit Breaker with Over-current Protection (Electronic)\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592285216917,"sku":"NB3LEG630-C25","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C25.png?v=1774843464"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-32a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 32A 30mA 6kA C-CURVE TYPE A","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Combined protection against overload, short-circuit, and residual current leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping type: \u003c\/strong\u003eElectronic (integrated residual current and thermal-magnetic release)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC Curve (5-10In): \u003c\/strong\u003eFor resistive and inductive loads with low inrush currents\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003e35 mm\u003cstrong\u003e \u003c\/strong\u003eDIN rail (EN 60715), quick clip-on design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications: \u003c\/strong\u003eResidential distribution boards, lighting control, and general-purpose low-voltage systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e32A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e1P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type:\u003c\/strong\u003e Type A (AC + pulsing DC)\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eResidual Making and Breaking Capacity (I△m):\u003c\/strong\u003e 3kA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 6kA\u003cbr\u003e\u003cstrong\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEG-40_RCBO.pdf?v=1774580645\" rel=\"noopener\" target=\"_blank\" title=\"NB3LEG-40 Residual Current Circuit Breaker with Over-current Protection (Electronic)\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592285249685,"sku":"NB3LEG630-C32","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C32.png?v=1774843720"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-40a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 40A 30mA 6kA C-CURVE TYPE A","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Combined protection against overload, short-circuit, and residual current leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping type: \u003c\/strong\u003eElectronic (integrated residual current and thermal-magnetic release)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC Curve (5-10In): \u003c\/strong\u003eFor resistive and inductive loads with low inrush currents\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003e35 mm\u003cstrong\u003e \u003c\/strong\u003eDIN rail (EN 60715), quick clip-on design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications: \u003c\/strong\u003eResidential distribution boards, lighting control, and general-purpose low-voltage systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e40A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e1P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type:\u003c\/strong\u003e Type A (AC + pulsing DC)\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eResidual Making and Breaking Capacity (I△m):\u003c\/strong\u003e 3kA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 6kA\u003cbr\u003e\u003cstrong\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEG-40_RCBO.pdf?v=1774580645\" rel=\"noopener\" target=\"_blank\" title=\"NB3LEG-40 Residual Current Circuit Breaker with Over-current Protection (Electronic)\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592285315221,"sku":"NB3LEG630-C40","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C40.png?v=1774848408"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c10a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C10A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592290295957,"sku":"NB2LE6-10A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-10A.png?v=1775703022"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c16a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C16A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592290328725,"sku":"NB2LE6-16A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-16A.png?v=1775702867"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c20a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C20A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 6A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592290427029,"sku":"NB2LE6-20A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-20A.png?v=1775699838"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c25a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C25A 30mA A-TYPE","description":"\u003cp\u003eThe CHINT NB2LE (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230\/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity and leakage sensitivities of 30mA, the NB2LE is reliable, compact, and compliant with IEC\/EN 61009-1 standards. \u003c\/p\u003e\u003cp\u003e\u003cstrong data-end=\"164\" data-start=\"138\"\u003eTripping Curve: Type C\u003c\/strong\u003e trips magnetically at approximately 5 to 10 times the rated current (In), while providing thermal tripping for overload conditions. It offers a balance between sensitivity and tolerance to moderate inrush currents.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A class\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar to suit: \u003c\/strong\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBB211710%2F18\u0026amp;_ss=e\u0026amp;_v=1.0#product-modal\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR NEEDLE-TYPE  FOR NB2LE COMPACT RCBO'S\"\u003eNeedle-Type\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/e-p-s.com.au\/products\/chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos?_pos=1\u0026amp;_psq=CBBSC2P\u0026amp;_ss=e\u0026amp;_v=1.0\" rel=\"noopener\" target=\"_blank\" title=\"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S\"\u003eBusbar Side Cap\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592290459797,"sku":"NB2LE6-25A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-25A.png?v=1775699707"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-50a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 50A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 50A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e50A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592290885781,"sku":"NB3LEU1030-C50","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C50.png?v=1774856272"},{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-10a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 10A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 400\/415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 10 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296063125,"sku":"NB3L-40-C10A","price":106.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C10A_66502f7e-4751-405e-9674-6e5c9a5edba1.png?v=1737094585"},{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-16a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 16A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 16 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail EN 60715 (35 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296095893,"sku":"NB3L-40-C16A","price":106.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C16A_269ef79f-d02d-46d3-952d-c13ea125d8a4.png?v=1737094590"},{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-20a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 20A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 20 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296128661,"sku":"NB3L-40-C20A","price":106.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C20A_91055b51-3b71-4475-9cd3-77784faf2041.png?v=1737094595"},{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-25a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 25A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 25 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296226965,"sku":"NB3L-40-C25A","price":106.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C25A_0cbe48f6-82f5-40d0-b35d-794a8c0b7acb.png?v=1737094600"},{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-32a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 32A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 32 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296259733,"sku":"NB3L-40-C32A","price":106.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C32A_c04e4088-5161-4778-9222-a6055a514a0b.png?v=1737094605"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c10a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C10A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThis NB3LEU-63 3P+N RCBO with 10A rating, 30mA sensitivity, and 10kA capacity. \u003c\/strong\u003eType A C-curve protection for three-phase systems. This RCBO provides effective protection against overloads, short circuits, and earth leakage, helping to prevent electric shock and equipment damage. The 10kA breaking capacity ensures reliable performance in installations with higher fault levels. The C-curve tripping allows the device to handle moderate inrush currents, making it suitable for a wide range of commercial and industrial applications. The Type A class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical loads.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 10A\u003cbr\u003e\u003cstrong\u003ePoles:\u003c\/strong\u003e 3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C-Curve\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type: \u003c\/strong\u003eType A (AC + pulsing DC)\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e10kA\u003cbr\u003e\u003cstrong\u003eMounting Method:\u003c\/strong\u003e DIN rail EN 60715 (35mm), fast clip device\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296292501,"sku":"NB3LEU63-C10A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C10A.png?v=1737094611"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c16a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C16A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e16A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296423573,"sku":"NB3LEU63-C16A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C16A.png?v=1737094615"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c20a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C20A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e20A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296456341,"sku":"NB3LEU63-C20A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C20A.png?v=1737094622"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c25a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C25A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e25A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296554645,"sku":"NB3LEU63-C25A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C25A.png?v=1737094627"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c32a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C32A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e32A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296587413,"sku":"NB3LEU63-C32A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C32A.png?v=1737094632"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c40a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C40A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e40A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297111701,"sku":"NB3LEU63-C40A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C40A.png?v=1737094637"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c50a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C50A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e50A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297144469,"sku":"NB3LEU63-C50A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C50A.png?v=1737094641"},{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-40a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 40A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 40 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297210005,"sku":"NB3L-40-C40A","price":126.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C40A_a7af4501-d15a-4c6a-9982-38cf9af4a0d5.png?v=1737094652"},{"product_id":"chint-busbar-side-cap-2pole-16mm-sqr-for-nb2le-compact-rcbos","title":"CHINT BUSBAR SIDE CAP 2POLE 16MM SQR FOR NB2LE COMPACT RCBO'S","description":"\u003cp\u003eBusbar side cap 2P 16mm2\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45890033156245,"sku":"CBBSC2P","price":0.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/busbarsidecap.png?v=1775716320"},{"product_id":"chint-busbar-needle-type-18-way-for-nb2le-compact-rcbos","title":"CHINT BUSBAR NEEDLE-TYPE 18-WAY FOR NB2LE COMPACT RCBO'S","description":"\u003cp\u003eThe \u003cstrong\u003eCHINT CBB-2 Busbar\u003c\/strong\u003e is designed for efficient power distribution and connection of modular low-voltage devices with 18 mm widths. It ensures safe, reliable, and simplified wiring in distribution panels. Engineered under IEC 60947-7 standards, it provides high conductivity, strong mechanical performance, and compatibility across CHINT’s NB1 and NB2 series modular devices.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: IEC 60947-7 compliant \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar Types\u003c\/strong\u003e: Pin in 18mm(upper interface)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Sectional Area\u003c\/strong\u003e: 10 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current\u003c\/strong\u003e: 63 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThickness\u003c\/strong\u003e: 1.5 mm copper bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation\u003c\/strong\u003e: Suitable for 18 mm modular devices (MCBs, RCCBs, RCBOs, SPDs)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45890033221781,"sku":"CBB211710\/18","price":27.47,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CBB211710_2018.png?v=1742873036"},{"product_id":"chint-nb2le-rcbo-compact-1p-n-6ka-c6a-30ma-a-type","title":"CHINT NB2LE RCBO COMPACT 1P+N 6kA C6A 30mA A-TYPE","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB2LE RCBO\u003c\/strong\u003e Compact is a space-saving and efficient solution for protecting electrical circuits from overloads, short circuits, and earth leakage. Designed with a 1P+N configuration, it combines the functions of an MCB and RCD into a single compact device\u003cstrong\u003e.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWith 30mA sensitivity, and 6kA breaking capacity\u003c\/strong\u003e, this RCBO provides reliable protection for residential and light commercial applications. The C-curve tripping characteristic allows it to handle moderate inrush currents, reducing nuisance tripping in everyday use.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTripping class: Type A\u003c\/strong\u003e detects \u0026amp;\u003cstrong\u003e \u003c\/strong\u003etrips on\u003cstrong\u003e \u003c\/strong\u003eAC sinusoidal residual currents and pulsating DC residual currents, ensuring protection where electronic loads may produce DC components. It provides standard earth leakage protection (e.g., 30 mA) with fast disconnection.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e AC 230\/240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 6A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e1P + N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Characteristics\u003c\/strong\u003e: Type C (5–10 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom top\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting: \u003c\/strong\u003eDIN rail \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB2LE_RCBO.pdf?v=1775630968\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB2LE RCBO 6kA 30mA A-TYPE\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45890067005589,"sku":"NB2LE6-06A","price":24.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB2LE6-40A.png?v=1775635165"}],"url":"https:\/\/e-p-s.com.au\/collections\/rcbo-1.oembed?page=9","provider":"EPS","version":"1.0","type":"link"}