{"title":"RCBO 3P+N 10kA 4 MODULE","description":"","products":[{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-10a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 10A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 400\/415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 10 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296063125,"sku":"NB3L-40-C10A","price":106.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C10A_66502f7e-4751-405e-9674-6e5c9a5edba1.png?v=1737094585"},{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-16a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 16A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 16 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail EN 60715 (35 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296095893,"sku":"NB3L-40-C16A","price":106.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C16A_269ef79f-d02d-46d3-952d-c13ea125d8a4.png?v=1737094590"},{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-20a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 20A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 20 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296128661,"sku":"NB3L-40-C20A","price":106.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C20A_91055b51-3b71-4475-9cd3-77784faf2041.png?v=1737094595"},{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-25a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 25A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 25 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296226965,"sku":"NB3L-40-C25A","price":106.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C25A_0cbe48f6-82f5-40d0-b35d-794a8c0b7acb.png?v=1737094600"},{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-32a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 32A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 32 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296259733,"sku":"NB3L-40-C32A","price":106.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C32A_c04e4088-5161-4778-9222-a6055a514a0b.png?v=1737094605"},{"product_id":"chint-nb3l-40-rcbo-3p-n-10ka-40a-c-curve-30ma-type-a-4-module","title":"CHINT NB3L-40 RCBO 3P+N 10kA 40A C CURVE 30mA Type A 4 MODULE","description":"\u003cp\u003eThe CHINT NB3L-40 RCBO combines residual current protection and over-current protection in one compact unit, offering reliable performance in low-voltage electrical systems. It safeguards circuits against overloads, short-circuits, and earth leakage faults, ensuring both equipment and personnel protection. Designed for 415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology  C-Curve. The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance. \u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification: \u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IEC\/EN 61009-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e: 415 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e: 40 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curves\u003c\/strong\u003e: C Curve: For mixed resistive\/inductive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current (IΔn)\u003c\/strong\u003e: 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Type\u003c\/strong\u003e: Type A \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN rail \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (3P+N)\u003c\/strong\u003e: Height: 85.5 mm, Width: 71.1 mm, Depth: 69.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3L-40_RCBO.pdf?v=1775803807\" rel=\"noopener\" target=\"_blank\" title=\"CHINT NB3L-40 RCBO 3P+N 10kA C CURVE 30mA Type A 4 MODULE\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297210005,"sku":"NB3L-40-C40A","price":126.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3L-40-C40A_a7af4501-d15a-4c6a-9982-38cf9af4a0d5.png?v=1737094652"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/collections\/NB3L-40-C25A.png?v=1774575757","url":"https:\/\/e-p-s.com.au\/collections\/rcbo-3p-n-10ka-4-module.oembed","provider":"EPS","version":"1.0","type":"link"}