{"title":"CHASSIS MOUNT RCBO","description":"","products":[{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-10a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 10A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 10A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592269521045,"sku":"NB3LEU1030-C10","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C10.png?v=1774852603"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-16a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 16A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 16A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003eC Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type: \u003c\/strong\u003eType A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592269553813,"sku":"NB3LEU1030-C16","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C16.png?v=1774854192"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-20a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 20A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 20A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592269652117,"sku":"NB3LEU1030-C20","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C20.png?v=1774855645"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-25a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 25A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 25A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592269750421,"sku":"NB3LEU1030-C25","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C25.png?v=1774855826"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-32a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 32A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 32A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e32A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592270110869,"sku":"NB3LEU1030-C32","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C32.png?v=1774856003"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-40a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 40A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 40A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e40A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592270209173,"sku":"NB3LEU1030-C40","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C40.png?v=1774856162"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-10a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 10A 30mA 6kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEG RCBO\u003c\/strong\u003e is a compact and reliable solution for combined overcurrent and residual current protection. Designed with a 1P+N configuration and single-module width, it saves space while delivering high-performance safety for modern electrical installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWith a 30mA sensitivity and 6kA breaking capacity\u003c\/strong\u003e, this RCBO ensures effective protection against overloads, short circuits, and earth leakage faults. The C-curve tripping characteristic allows it to handle moderate inrush currents, making it suitable for a wide range of applications. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThe Type A \u003c\/strong\u003eRCD functionality provides enhanced protection by detecting both AC and pulsating DC residual currents, making it ideal for circuits with electronic devices.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e10A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e1P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eC-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A (AC + pulsing DC)\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e240V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e6kA\u003cstrong\u003e\u003cbr\u003eMounting Method: \u003c\/strong\u003e35 mm DIN rail (EN 60715), quick clip-on design.\u003cstrong\u003e\u003cbr\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEG-40_RCBO.pdf?v=1774580645\" rel=\"noopener\" target=\"_blank\" title=\"NB3LEG-40 Residual Current Circuit Breaker with Over-current Protection (Electronic)\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592284922005,"sku":"NB3LEG630-C10","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C10_db14bc28-baa3-4d80-9be6-f9e4bfeb22d5.png?v=1774582125"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-16a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 16A 30mA 6kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEG RCBO\u003c\/strong\u003e is a compact and reliable solution for combined overcurrent and residual current protection. Designed with a 1P+N configuration and single-module width, it saves space while delivering high-performance safety for modern electrical installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWith a 30mA sensitivity and 6kA breaking capacity\u003c\/strong\u003e, this RCBO ensures effective protection against overloads, short circuits, and earth leakage faults. The C-curve tripping characteristic allows it to handle moderate inrush currents, making it suitable for a wide range of applications. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThe Type A\u003c\/strong\u003e RCD functionality provides enhanced protection by detecting both AC and pulsating DC residual currents, making it ideal for circuits with electronic devices.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e16A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e1P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eC-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A (AC + pulsing DC)\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e240V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e6kA\u003cstrong\u003e\u003cbr\u003eMounting Method: \u003c\/strong\u003e35 mm DIN rail (EN 60715), quick clip-on design.\u003cstrong\u003e\u003cbr\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592285085845,"sku":"NB3LEG630-C16","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C16.png?v=1774842921"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-20a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 20A 30mA 6kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEG RCBO\u003c\/strong\u003e is a compact and reliable solution for combined overcurrent and residual current protection. Designed with a 1P+N configuration and single-module width, it saves space while delivering high-performance safety for modern electrical installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWith a 30mA sensitivity and 6kA breaking capacity\u003c\/strong\u003e, this RCBO ensures effective protection against overloads, short circuits, and earth leakage faults. The C-curve tripping characteristic allows it to handle moderate inrush currents, making it suitable for a wide range of applications. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThe Type A\u003c\/strong\u003e RCD functionality provides enhanced protection by detecting both AC and pulsating DC residual currents, making it ideal for circuits with electronic devices.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e20A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e1P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eC-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A (AC + pulsing DC)\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e240V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e6kA\u003cstrong\u003e\u003cbr\u003eMounting Method: \u003c\/strong\u003e35 mm DIN rail (EN 60715), quick clip-on design.\u003cstrong\u003e\u003cbr\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEG-40_RCBO.pdf?v=1774580645\" rel=\"noopener\" target=\"_blank\" title=\"NB3LEG-40 Residual Current Circuit Breaker with Over-current Protection (Electronic)\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592285184149,"sku":"NB3LEG630-C20","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C20.png?v=1774843192"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-25a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 25A 30mA 6kA C-CURVE TYPE A","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Combined protection against overload, short-circuit, and residual current leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping type: \u003c\/strong\u003eElectronic (integrated residual current and thermal-magnetic release)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC Curve (5-10In): \u003c\/strong\u003eFor resistive and inductive loads with low inrush currents\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003e35 mm\u003cstrong\u003e \u003c\/strong\u003eDIN rail (EN 60715), quick clip-on design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications: \u003c\/strong\u003eResidential distribution boards, lighting control, and general-purpose low-voltage systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e25A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e1P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type:\u003c\/strong\u003e Type A (AC + pulsing DC)\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eResidual Making and Breaking Capacity (I△m):\u003c\/strong\u003e 3kA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 6kA\u003cbr\u003e\u003cstrong\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEG-40_RCBO.pdf?v=1774580645\" rel=\"noopener\" target=\"_blank\" title=\"NB3LEG-40 Residual Current Circuit Breaker with Over-current Protection (Electronic)\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592285216917,"sku":"NB3LEG630-C25","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C25.png?v=1774843464"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-32a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 32A 30mA 6kA C-CURVE TYPE A","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Combined protection against overload, short-circuit, and residual current leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping type: \u003c\/strong\u003eElectronic (integrated residual current and thermal-magnetic release)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC Curve (5-10In): \u003c\/strong\u003eFor resistive and inductive loads with low inrush currents\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003e35 mm\u003cstrong\u003e \u003c\/strong\u003eDIN rail (EN 60715), quick clip-on design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications: \u003c\/strong\u003eResidential distribution boards, lighting control, and general-purpose low-voltage systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e32A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e1P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type:\u003c\/strong\u003e Type A (AC + pulsing DC)\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eResidual Making and Breaking Capacity (I△m):\u003c\/strong\u003e 3kA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 6kA\u003cbr\u003e\u003cstrong\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEG-40_RCBO.pdf?v=1774580645\" rel=\"noopener\" target=\"_blank\" title=\"NB3LEG-40 Residual Current Circuit Breaker with Over-current Protection (Electronic)\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592285249685,"sku":"NB3LEG630-C32","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C32.png?v=1774843720"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-40a-30ma-6ka-c-curve-type-a","title":"CHINT RCBO NB3LEG 1P+N 1 MODULE + P\/TAIL 40A 30mA 6kA C-CURVE TYPE A","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Combined protection against overload, short-circuit, and residual current leakage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping type: \u003c\/strong\u003eElectronic (integrated residual current and thermal-magnetic release)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC Curve (5-10In): \u003c\/strong\u003eFor resistive and inductive loads with low inrush currents\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003e35 mm\u003cstrong\u003e \u003c\/strong\u003eDIN rail (EN 60715), quick clip-on design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e98 H x 18 W x 77 D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications: \u003c\/strong\u003eResidential distribution boards, lighting control, and general-purpose low-voltage systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e40A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e1P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type:\u003c\/strong\u003e Type A (AC + pulsing DC)\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eResidual Making and Breaking Capacity (I△m):\u003c\/strong\u003e 3kA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 6kA\u003cbr\u003e\u003cstrong\u003eRated Insulation Voltage (Ui): \u003c\/strong\u003e500V\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEG-40_RCBO.pdf?v=1774580645\" rel=\"noopener\" target=\"_blank\" title=\"NB3LEG-40 Residual Current Circuit Breaker with Over-current Protection (Electronic)\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592285315221,"sku":"NB3LEG630-C40","price":37.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEG630-C40.png?v=1774848408"},{"product_id":"chint-rcbo-nb3leu-1p-n-1-module-p-tail-50a-30ma-10ka-c-curve-type-a","title":"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL 50A 30mA 10kA C-CURVE TYPE A","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT 1P+N RCBO 50A 30mA 10kA C Curve Type A with pigtail \u003c\/strong\u003eis a compact, high-performance circuit protection device designed for modern electrical installations. It combines residual current protection and overcurrent protection in a single module, ensuring safety against electrical shock, overload, and short circuit.  \u003c\/p\u003e\u003cp\u003eWith a 30mA sensitivity, this RCBO provides essential protection for people, while the 10kA breaking capacity ensures reliable performance under fault conditions. The C curve characteristic makes it suitable for circuits with moderate inrush currents such as lighting and power outlets. The Type A RCD ensures detection of both AC and pulsating DC residual currents, making it suitable for circuits with electronic equipment.\u003c\/p\u003e\u003cp\u003eDesigned for DIN rail mounting, the NB3LEU range is ideal for residential, commercial, and light industrial applications, offering fast disconnection and dependable operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003esafety standard for RCBOs. Ensures the device provides reliable protection and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e50A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e1P+N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e500V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method: \u003c\/strong\u003eDin rail EN 60715 (35 mm) with fast clip-on design. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (mm): \u003c\/strong\u003e110 H x 18 W x 76.5 D\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU_CHINT_RCBO_1_MODULE_PTAIL_C-CURVE_TYPE_A.pdf?v=1774850450\" target=\"_blank\" title=\"CHINT RCBO NB3LEU 1P+N 1 MODULE + P\/TAIL\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592290885781,"sku":"NB3LEU1030-C50","price":42.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU1030-C50.png?v=1774856272"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c10a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C10A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThis NB3LEU-63 3P+N RCBO with 10A rating, 30mA sensitivity, and 10kA capacity. \u003c\/strong\u003eType A C-curve protection for three-phase systems. This RCBO provides effective protection against overloads, short circuits, and earth leakage, helping to prevent electric shock and equipment damage. The 10kA breaking capacity ensures reliable performance in installations with higher fault levels. The C-curve tripping allows the device to handle moderate inrush currents, making it suitable for a wide range of commercial and industrial applications. The Type A class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical loads.\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 10A\u003cbr\u003e\u003cstrong\u003ePoles:\u003c\/strong\u003e 3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C-Curve\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type: \u003c\/strong\u003eType A (AC + pulsing DC)\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e10kA\u003cbr\u003e\u003cstrong\u003eMounting Method:\u003c\/strong\u003e DIN rail EN 60715 (35mm), fast clip device\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296292501,"sku":"NB3LEU63-C10A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C10A.png?v=1737094611"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c16a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C16A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e16A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296423573,"sku":"NB3LEU63-C16A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C16A.png?v=1737094615"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c20a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C20A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e20A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296456341,"sku":"NB3LEU63-C20A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C20A.png?v=1737094622"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c25a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C25A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e25A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296554645,"sku":"NB3LEU63-C25A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C25A.png?v=1737094627"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c32a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C32A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e32A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592296587413,"sku":"NB3LEU63-C32A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C32A.png?v=1737094632"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c40a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C40A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e40A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297111701,"sku":"NB3LEU63-C40A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C40A.png?v=1737094637"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c50a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C50A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e50A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297144469,"sku":"NB3LEU63-C50A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C50A.png?v=1737094641"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-c63a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N C63A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003e\u003cstrong\u003eThe CHINT NB3LEU-63 RCBO\u003c\/strong\u003e is a high-performance protective device designed for three-phase electrical systems, combining overcurrent and residual current protection in one unit. With a 3P+N configuration and compact 3-module chassis, it delivers efficient protection while optimising switchboard space.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical load. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC- Curve\u003c\/strong\u003e breakers allow short bursts of higher current (like equipment starts up) without tripping, but still protect the circuit from overloads and faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e ensures reliable performance in installations with higher fault levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection: \u003c\/strong\u003eFrom bottom\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e63A\u003cbr\u003e\u003cstrong\u003ePoles: \u003c\/strong\u003e3P+N\u003cbr\u003e\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003cbr\u003e\u003cstrong\u003eLeakage Detection Type\u003c\/strong\u003e: Type A\u003cbr\u003e\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 400\/415V AC\u003cbr\u003e\u003cstrong\u003eRated Sensitivity (I△n):\u003c\/strong\u003e 30mA\u003cbr\u003e\u003cstrong\u003eRated Short-circuit Capacity (Icn):\u003c\/strong\u003e 10kA\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003e\u003cstrong\u003eDownload Datasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297177237,"sku":"NB3LEU63-C63A","price":150.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-C63A.png?v=1737094647"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-d20a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N D20A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003eNB3LEU-63 circuit breaker, mainly used for AC 50Hz \/60Hz, rated voltage\u003cbr\u003eAC 400V\/415V (while working normally within the voltage range from 340V\u003cbr\u003eto 457 V), rated current 10A to 63A, overload, short circuit and leakage\u003cbr\u003eprotection of electrical lines and equipment, can also be used as\u003cbr\u003einfrequent connection and disconnection of the line.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical loads. \u003c\/li\u003e\n\u003cli\u003eA \u003cstrong data-end=\"192\" data-start=\"165\"\u003eD-curve\u003c\/strong\u003e is designed to tolerate high inrush currents and trips only when the current reaches about 10 to 20 times the rated current instantly (magnetic trip). It also provides standard thermal protection for overloads. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e20A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e3P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eD-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e400\/415V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e10kA\u003cstrong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297275541,"sku":"NB3LEU63-D20A","price":165.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-D20A.png?v=1737094657"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-d25a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N D25A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003eNB3LEU-63 circuit breaker, mainly used for AC 50Hz \/60Hz, rated voltage\u003cbr\u003eAC 400V\/415V (while working normally within the voltage range from 340V\u003cbr\u003eto 457 V), rated current 10A to 63A, overload, short circuit and leakage\u003cbr\u003eprotection of electrical lines and equipment, can also be used as\u003cbr\u003einfrequent connection and disconnection of the line.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical loads. \u003c\/li\u003e\n\u003cli\u003eA \u003cstrong data-end=\"192\" data-start=\"165\"\u003eD-curve\u003c\/strong\u003e is designed to tolerate high inrush currents and trips only when the current reaches about 10 to 20 times the rated current instantly (magnetic trip). It also provides standard thermal protection for overloads. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e25A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e3P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eD-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e400\/415V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e10kA\u003cstrong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297308309,"sku":"NB3LEU63-D25A","price":165.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-D25A.png?v=1737094661"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-d32a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N D32A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003eNB3LEU-63 circuit breaker, mainly used for AC 50Hz \/60Hz, rated voltage\u003cbr\u003eAC 400V\/415V (while working normally within the voltage range from 340V\u003cbr\u003eto 457 V), rated current 10A to 63A, overload, short circuit and leakage\u003cbr\u003eprotection of electrical lines and equipment, can also be used as\u003cbr\u003einfrequent connection and disconnection of the line.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical loads. \u003c\/li\u003e\n\u003cli\u003eA \u003cstrong data-end=\"192\" data-start=\"165\"\u003eD-curve\u003c\/strong\u003e is designed to tolerate high inrush currents and trips only when the current reaches about 10 to 20 times the rated current instantly (magnetic trip). It also provides standard thermal protection for overloads. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e32A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e3P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eD-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e400\/415V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e10kA\u003cstrong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297341077,"sku":"NB3LEU63-D32A","price":165.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-D32A.png?v=1737094665"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-d40a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N D40A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003eNB3LEU-63 circuit breaker, mainly used for AC 50Hz \/60Hz, rated voltage\u003cbr\u003eAC 400V\/415V (while working normally within the voltage range from 340V\u003cbr\u003eto 457 V), rated current 10A to 63A, overload, short circuit and leakage\u003cbr\u003eprotection of electrical lines and equipment, can also be used as\u003cbr\u003einfrequent connection and disconnection of the line.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical loads. \u003c\/li\u003e\n\u003cli\u003eA \u003cstrong data-end=\"192\" data-start=\"165\"\u003eD-curve\u003c\/strong\u003e is designed to tolerate high inrush currents and trips only when the current reaches about 10 to 20 times the rated current instantly (magnetic trip). It also provides standard thermal protection for overloads. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e40A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e3P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eD-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e400\/415V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e10kA\u003cstrong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297373845,"sku":"NB3LEU63-D40A","price":165.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-D40A.png?v=1737094670"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-d50a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N D50A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003eNB3LEU-63 circuit breaker, mainly used for AC 50Hz \/60Hz, rated voltage\u003cbr\u003eAC 400V\/415V (while working normally within the voltage range from 340V\u003cbr\u003eto 457 V), rated current 10A to 63A, overload, short circuit and leakage\u003cbr\u003eprotection of electrical lines and equipment, can also be used as\u003cbr\u003einfrequent connection and disconnection of the line.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical loads. \u003c\/li\u003e\n\u003cli\u003eA \u003cstrong data-end=\"192\" data-start=\"165\"\u003eD-curve\u003c\/strong\u003e is designed to tolerate high inrush currents and trips only when the current reaches about 10 to 20 times the rated current instantly (magnetic trip). It also provides standard thermal protection for overloads. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e50A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e3P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eD-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e400\/415V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e10kA\u003cstrong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297406613,"sku":"NB3LEU63-D50A","price":165.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-D50A.png?v=1737094675"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-d63a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N D63A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003eNB3LEU-63 circuit breaker, mainly used for AC 50Hz \/60Hz, rated voltage\u003cbr\u003eAC 400V\/415V (while working normally within the voltage range from 340V\u003cbr\u003eto 457 V), rated current 10A to 63A, overload, short circuit and leakage\u003cbr\u003eprotection of electrical lines and equipment, can also be used as\u003cbr\u003einfrequent connection and disconnection of the line.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical loads. \u003c\/li\u003e\n\u003cli\u003eA \u003cstrong data-end=\"192\" data-start=\"165\"\u003eD-curve\u003c\/strong\u003e is designed to tolerate high inrush currents and trips only when the current reaches about 10 to 20 times the rated current instantly (magnetic trip). It also provides standard thermal protection for overloads. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e63A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e3P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eD-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e400\/415V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e10kA\u003cstrong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45592297504917,"sku":"NB3LEU63-D63A","price":165.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-D63A.png?v=1737094680"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-d10a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N D10A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003eNB3LEU-63 circuit breaker, mainly used for AC 50Hz \/60Hz, rated voltage\u003cbr\u003eAC 400V\/415V (while working normally within the voltage range from 340V\u003cbr\u003eto 457 V), rated current 10A to 63A, overload, short circuit and leakage\u003cbr\u003eprotection of electrical lines and equipment, can also be used as\u003cbr\u003einfrequent connection and disconnection of the line.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical loads. \u003c\/li\u003e\n\u003cli\u003eA \u003cstrong data-end=\"192\" data-start=\"165\"\u003eD-curve\u003c\/strong\u003e is designed to tolerate high inrush currents and trips only when the current reaches about 10 to 20 times the rated current instantly (magnetic trip). It also provides standard thermal protection for overloads. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e10A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e3P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eD-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e400\/415V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e10kA\u003cstrong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"CHINT","offers":[{"title":"EA","offer_id":45890058190997,"sku":"NB3LEU63-D10A","price":165.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-D10A.png?v=1742873229"},{"product_id":"chint-rcbo-nb3leu-63-3p-n-d16a-30ma-10ka-3-module-type-a-chassis","title":"CHINT RCBO NB3LEU-63 3P+N D16A 30mA 10kA 3 MODULE TYPE A CHASSIS","description":"\u003cp\u003eNB3LEU-63 circuit breaker, mainly used for AC 50Hz \/60Hz, rated voltage\u003cbr\u003eAC 400V\/415V (while working normally within the voltage range from 340V\u003cbr\u003eto 457 V), rated current 10A to 63A, overload, short circuit and leakage\u003cbr\u003eprotection of electrical lines and equipment, can also be used as\u003cbr\u003einfrequent connection and disconnection of the line.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with IEC\/EN 61009-1\u003c\/strong\u003e safety standard for RCBOs. Ensures the device provides reliable protection against electric shock, overload and short circuits, and meets strict performance and safety requirements for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType A\u003c\/strong\u003e class Trip on both AC and pulsing DC leakage currents, whether they rise quickly or slowly, ensuring reliable protection for modern electrical loads. \u003c\/li\u003e\n\u003cli\u003eA \u003cstrong data-end=\"192\" data-start=\"165\"\u003eD-curve\u003c\/strong\u003e is designed to tolerate high inrush currents and trips only when the current reaches about 10 to 20 times the rated current instantly (magnetic trip). It also provides standard thermal protection for overloads. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail EN 60715 (35mm) by means of a fast clip device \u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRated Current (In): \u003c\/strong\u003e16A\u003cstrong\u003e\u003cbr\u003ePoles: \u003c\/strong\u003e3P+N\u003cstrong\u003e\u003cbr\u003eTripping Curve: \u003c\/strong\u003eD-Curve\u003cstrong\u003e\u003cbr\u003eLeakage Detection Type: \u003c\/strong\u003eType A\u003cstrong\u003e\u003cbr\u003eRated Voltage (Ue): \u003c\/strong\u003e400\/415V AC\u003cstrong\u003e\u003cbr\u003eRated Sensitivity (I△n): \u003c\/strong\u003e30mA\u003cstrong\u003e\u003cbr\u003eRated Short-circuit Capacity (Icn): \u003c\/strong\u003e10kA\u003cstrong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/CHINT_NB3LEU63_CHINT_RCBO_3_MODULE_TYPE_A_CHASSIS_e2e3810b-8140-45d1-a9d6-9d987cb9b908.pdf?v=1774857728\" target=\"_blank\" title=\"CHINT RCBO NB3LEU-63 3P+N 30mA 10kA 3 MODULE TYPE A CHASSIS\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"EPS","offers":[{"title":"EA","offer_id":45890058944661,"sku":"NB3LEU63-D16A","price":165.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/files\/NB3LEU63-D16A.png?v=1742873232"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/6370\/5749\/collections\/NB3LEU63-D40A_a2577bd8-fafe-4e88-8726-561014d6f8dc.png?v=1774576334","url":"https:\/\/e-p-s.com.au\/collections\/rcbo-3p-n-c25a-10ka-3-module-type-a-chassis.oembed","provider":"EPS","version":"1.0","type":"link"}